Welcome to lesson 1. Everything you will do in an anesthetic, from a phenylephrine bolus to a unit of blood, lands on the four knobs in this lesson.
- Walk the cardiac cycle and draw it as a pressure-volume loop
- Separate preload, afterload, contractility and compliance, and predict what each one does to stroke volume
- Balance myocardial oxygen supply against demand, including coronary perfusion pressure and diastolic time
Every screen is one idea. Tap the interactives: they are where the learning sticks. Terms are defined the first time they appear.
Mrs. A, 78, 62 kg. History of hypertension and stable angina. The surgeon is prepping while you position the leg.
She is light. Her heart rate climbs, her pressure falls, and the ST segment in lead V5 starts to sag.
- Why does a fast heart rate hurt this heart twice over?
- What single number tells you whether her coronaries are still being fed?
- Which drug do you reach for, and what will it do to her pressure-volume loop?
You will answer all three at the end of the lesson.
Put the phases of one left ventricular beat in order, starting with the atrial kick. Tap them one at a time.
- LV pressure
- About 120 / 8 mmHg
- RV pressure
- About 25 / 4 mmHg
- Volumes
- EDV about 120 mL, ESV about 50 mL
- Heart sounds
- S1 = mitral and tricuspid closing. S2 = aortic and pulmonic closing
EDV is end-diastolic volume, the fullest the ventricle gets. ESV is end-systolic volume, what is left after the squeeze.
Plot ventricular pressure against ventricular volume and one beat becomes a loop that runs counterclockwise. Tap each part.
Tap a part of the loop above. Width is stroke volume. Area inside is stroke work.
The bottom limb, running left to right. The mitral valve is open and volume climbs from ESV to EDV while pressure stays low. The right-hand end of this limb is end-diastole.
The right-hand vertical limb. Both valves are shut, so volume cannot change while pressure shoots up. It ends when LV pressure passes aortic diastolic pressure and the aortic valve opens.
The top limb, running right to left. Volume falls by the stroke volume. Pressure peaks early then falls, and the aortic valve shuts at the top left corner.
The left-hand vertical limb. Both valves shut again, pressure falls fast at fixed volume. This is an active, ATP-requiring step: ischemia makes relaxation fail before contraction fails.
The line every loop's top left corner lands on. Its slope is contractility (Ees). Steeper slope means the ventricle empties to a smaller volume against the same pressure. Unlike ejection fraction, this slope does not change when you change load.
The curve every loop's bottom right corner lands on. Its steepness is diastolic stiffness, the inverse of compliance. A stiff ventricle needs a much higher filling pressure for the same volume.
Four different things, often confused. Pick one at a time.
- Strictly, the sarcomere stretch at end-diastole. In practice, end-diastolic volume
- What you can measure: LVEDP, pulmonary artery occlusion pressure, CVP for the right side, echo LV end-diastolic area
- Raised by volume, Trendelenburg, venoconstriction, slower rate (longer filling time)
- Lowered by hemorrhage, venodilators such as nitroglycerin, high airway pressure, sitting or beach chair position
- On the loop: the bottom right corner slides right, so the loop gets wider
- Strictly, ventricular wall stress during ejection, not just blood pressure
- What you can measure: systemic vascular resistance, aortic systolic pressure, arterial elastance
- Raised by vasoconstrictors, aortic stenosis, cross clamping, hypothermia, light anesthesia
- Lowered by vasodilators, sepsis, neuraxial block, volatile anesthetics
- On the loop: the top gets taller and the loop gets narrower, so end-systolic volume rises
- Strictly, force generated at any given preload and afterload, so it is load independent
- Best single index: the slope of the ESPVR (Ees). Ejection fraction is a load-dependent stand-in
- Raised by beta-1 agonists, calcium, digoxin, phosphodiesterase inhibitors, faster rate (the Bowditch or treppe effect)
- Lowered by beta blockers, calcium channel blockers, volatile agents, propofol, acidosis, ischemia, hypothermia
- On the loop: the ESPVR line rotates up and left, so the ventricle empties further
- Compliance is change in volume divided by change in pressure during diastole
- A stiff (low compliance) ventricle shows a high filling pressure at a normal volume
- Causes of stiffness: hypertrophy, ischemia, aging, restrictive or infiltrative disease, tamponade from outside
- Stiff ventricles are kick dependent and rate sensitive: they want sinus rhythm and time to fill
- On the loop: the EDPVR curve rises, so the same volume sits at a much higher pressure
That was the first 5 screens. The other 17 are free with an account, plus this lesson’s cheat sheet and memory cards.
- A 50-question diagnostic, scored by NCE domain
- 5 full lessons with cheat sheets and memory cards
- Free practice questions and progress tracking
- A study plan and reminders built around your exam date
No card needed. You pick up right here after you sign up.